Pressure Gauges
   
  Temperature Gauge
   
  Digital Gauge
   
  Tester
Yash International  
EnglishJapaneseSpanishFrenchItalian
 
 

 
Temperature reflects the momentous thermal condition of a homogenous material. Measurement of temperature normally requires close, direct contact between the material and the sensor in such a manner that the sensor responds quickly to the temperature of the material.
 
CAPILLARY TYPE TEMPERATURE GAUGE
 
   
Sometimes the liquid/ gas or any other medium on which the temperature has to be gauged is away in distance or the application is at different site for which these 3 way micro bore SS 304 Capillary is installed/added to the bottom / back connection temperature gauge to gauge temperature of that application. These SS 304 capillary length vary from 1 meter to 50 meter as per client application and temperature is gauged using gas in filled / mercury element
 
   
   

Technical Specifications

MFG Standard

ASME B40

Scale Dial 63mm, 100mm, 150mm
Scale Range -40° C to 600 Deg C..… all measuring units to scale temperature
Accuracy ±2 % of FSD
Over limit temperature 15% of full scale range or 600°C whichever is min
Scales °C (standard), °F, Dual Scale °C/°F
   
Case & Ring AISI 304 SS (BAYONET LOCK TYPE)
Socket Stem: 316 SS
Stem Capillary length S.S.316 Armor Capillary (From 1 meter - upto 50 meters available)
Stem dia 6mm, 8mm, 10mm, 12mm, 14mm
Stem length AISI 316 SS upto 2 meters
Pressure element Mercury in Steel / gas in metal
   
Dial Aluminium Pointer, black graduation on white background
Pointer Aluminium, micro zero adjustment
Protection  Weatherproof IP 65, SAFETY PATTERN GAUGE TO EN871
Thread Connection 1/4", 3/8", 1/2" BSP & NPT or adjustable flexible / All angle connection
   
Gasket Neoprene
Mounting Bottom, Back
Optional Thermowell


ELECTRIC CONTACT (CAPILLARY) TEMPERATURE GAUGE WITH THERMOWELL
   
Electric contact thermometers are made of bulb, transmitting capillary and flat bourdon tube that are pressure filled with Mercury or gas filling. Contacts are mounted on mechanical dial Gauge to “Make or Break” an electronic control cycle depending on the position of the Instrument's pointer. SS 204 Capillary is also used to measure temperature on the application which is at a distance. It is an economical, rugged, reliable and precise temperature measuring instruments. These gauges can be used for different monitoring, measurement and control of line pressure by switching “on or off” electrical equipment. It is one of the most versatile and widely used devices in industrial temperature measurements.
 
   
   

Technical Specifications

MFG Standard

ASME B40

Scale Dial 100mm, 150mm
Scale Range -40° C to 600 Deg C… all measuring units to scale temperature
Accuracy ±1.6 % of FSD
Over limit temperature 15% of full scale range or 600°C whichever is min
Scales °C (standard), °F, Dual Scale °C/°F
   
Case & Ring AISI 304 SS (BAYONET LOCK TYPE)
Socket Stem: 316 SS
Stem Capillary length S.S.316 Armor Capillary (1 meter - upto 50 meters available)
Stem dia 6mm, 8mm, 10mm, 12mm, 14mm
Stem length AISI 316 SS upto 2 meters
Pressure element Mercury in Steel / gas in metal
   
Case & Bezel Die-cast aluminum weather proof stove enamel black finished case & bezel to ensure IP-55 as per IS-2147 suitable for use outdoor application without any additional protection.
Dial & Scale Dial will be made of suitable material black figure on white background with anti-corrosive finished scale and marking over an arc of 2700 confirming to BS-5235 non –reflective and marking as per IS-3602
Mounting Surface mounting bottom entry
Window Acrylic
External zero adjustment Provided by the side of the case if found error in reading it can be adjusted by the help of screw driver from outside without opening case & bezel.
Contacts Type Attachment 1NO, 1NC (Singe contact), 1NO / NC (2 contacts), 2 NO/ NC (4 contacts). SPDT type Electro Mechanical Magnetic snaps action contact for high and very high normally open independently adjustable to close on rise of temperature. The adjustable switch point indicator is fitted on the front of dial it can be adjusted by pushing and rotating the rotary stem pointer /contact will be fixed to the inner surface of the top glass cover. Set point and adjustment hole in the glass protected by a screw cap against splash water / dust. The top glass cover is easily removable for maintenance without affecting the set point.
Contact Rating 240V AC, 30 VA or 30watts at 220V AC
Junction box Provided at the bottom of the case.
   
     
 
Copyright © 2006 - 2014 Yash International. All Rights Reserved.
Best viewed on 1024x768 resolution.
Visit Our Other Website : www.yashvalves.com yashflowmeters.com  www.pressureinstruments.co.in